Showing posts with label Gas Detction System. Show all posts
Showing posts with label Gas Detction System. Show all posts

Friday, 2 November 2012

Saraswat Group :: Reticulated Pipe Fittings


SALIENT FEATURES :-
• 24 hours gas supply at your command. 
• No cylinder in the kitchen or inside the flat / resturants.    
• No holiday for Gas supply.  
• No follow up with LPG Distributor. 
• No waiting list for new connection or refill.  
• No entry to delivery boy inside the house.   
• No handling of cylinders by elders or younger generation.  
• LPG cylinder are handled by  trained mechanic.  
• Gas meter for recording on actual consumption.  
• 3rd party accident & loss of property insurance.    
• Entire system is as per IS code  6044 Part I  & OISD -162.  

     We offer reticulated systems for domestic & commercial locations with Over Pressure & Under pressure protections for reduce mishapnings. 

Saraswat Group has extensive experience in LPG / propane multi cylinder gas installations we have been in this business for last 12 years. We have a team of experienced engineers who handle the gas systems properly. We are provide Reticulated Pipe Fittings, LPG services India, LPG detection and monitoring system, Industrial and commercial burners, LPG Reticulated System, Propane gas Installations, Propane Tank Installation, Gas Manifold system, Industrial Gas Manifolds, LPG Tank Installation, Gas pipeline contractors, Gas Handling Equipments & Combustion Control Product

Friday, 19 October 2012

Saraswat Group :: Gas Governers


All propane  and L.P Gas applications require the use of a regulator. Because pressures in propane tanks can fluctuate significantly, regulators must be present to deliver a steady flow pressure to downstream appliances. 

These regulators normally compensate for tank pressures in from as little as 30psig to in excess of 200 psig and commonly deliver 11 inches water column for residential applications and 35 inches of water column, (27.7 inches of water column equals 1 pound per square inch), for industrial applications. Propane regulators differ in size and shape, delivery pressure and adjust-ability but are uniform in their purpose to deliver a constant outlet pressure for downstream requirements. 

As is the case in all regulators, outlet pressure is lower than inlet pressure. some pressure drop is observed in regulator  so in choosing the perfact regulator for differnt  process please see the graph of pressuer drop with quantity of flow  required. 

Saraswat Group has extensive experience in LPG / propane multi cylinder gas installations we have been in this business for last 12 years. We have a team of experienced engineers who handle the gas systems properly. We are provide Reticulated Pipe Fittings, LPG services India, LPG detection and monitoring system, Industrial and commercial burners, LPG Reticulated System, Propane gas Installations, Propane Tank Installation, Gas Manifold system, Industrial Gas Manifolds, LPG Tank Installation, Gas pipeline contractors, Gas Handling Equipments & Combustion Control Product.

Thursday, 11 October 2012

Saraswat Group :: Ball Valves


We offer  Ball  Valves For  L.P gas  installations use. these valves is aproved by American Gas association &  American Petroleum  institute for   gas handling.  the valves we offer is C.S forged body   Class - 150# , Class  300#  & Class  800#   in flange , SW & screwd  type   in sizes   10  MM to  80 MM ie 3/8"  to  3".

These Valves is   Also available in full steel forged bodies.

Saraswat Group has extensive experience in LPG / propane multi cylinder gas installations we have been in this business for last 12 years. We have a team of experienced engineers who handle the gas systems properly. We are provide Reticulated Pipe Fittings, LPG services India, LPG detection and monitoring system, Industrial and commercial burners, LPG Reticulated System, Propane gas Installations, Propane Tank Installation, Gas Manifold system, Industrial Gas Manifolds, LPG Tank Installation, Gas pipeline contractors, Gas Handling Equipments & Combustion Control Product.

Monday, 24 September 2012

Saraswat Group :: GAS METER



A meter is used to measure the volume of fuel gases / fuels such as natural gas and LPG/propane & HSD. meters are used at residential, commercial, and industrial applications that consume fuel gas supplied by a gas utility. Gases are more difficult to measure than liquids, as measured volumes are highly affected by temperature and pressure. Gas meters measure a defined volume, regardless of the pressurized quantity or quality of the gas flowing through the meter. Temperature, pressure and heating value compensation must be made to measur actual amount and value of gas moving through a meter. Several different designs of gas meters are in commonly used . we offer these meters up to 12 Bar Line pressure which is diaphragm & rotery type meters as per line pressure requirments.


Web Hosting
Email Solution
Website Company
Domain Registration
Domain Name Registration Service

Friday, 21 September 2012

Saraswat Group :: Adjustable Regulator (Gas Regulators)

These Regulators have wider outlet pressure ranges. The outlet pressure can be easily adjustable by rotating the adjustable screw. when we rotate anticlockwise the outlet pressure is reduced & by rotating it in clock wise direction the our PRESSURE REDUING VALVE / REGULATOR



A pressure regulator is a valve that automatically cuts off the flow of a liquid or gas at a certain pressure. Regulators are used to allow high-pressure fluid supply lines or tanks to be reduced to safe and/or usable pressures for various applications ie Oxy-fuel welding and cutting, propane and LP Gas applications, Oil and Gas Industry, Mining Industry. Gas pressure regulators are used to regulate the gas pressure and are not appropriate for measuring flow rates. A pressure regulator's primary function is to match the flow of gas through the regulator to the demand for gas placed upon the system. If the load flow decreases, then the regulator flow must decrease also. If the load flow increases, then the regulator flow must increase in order to keep the controlled pressure from decreasing due to a shortage of gas in the pressure system. Thes regulators are available in Two stages first called First stage Reulator & than second stage Regulator. These regulators are available in two types the one is adjustable type & another is Preset type.

FIRST STAGE REGULATOR
The first stage of the regulator is mounted to the cylinder /Tank Presure by a siutable means. It reduces cylinder pressure to a middle or intermediate pressure, usually about 1 bar to 10 bars (15 psig to 150 psi) higher than the ambient pressure. these regulators are balanced type by Mean of diaphragm & spring mechanism. A balanced regulator first stage automatically keeps a constant pressure difference between the interstage pressure and the ambient pressure even as the tank pressure drops with consumption. The balanced regulator design allows the first stage orifice to be as large as needed without incurring performance degradation as a result of changing tank / cylinder pressure.

SECOND STAGE REGULATOR
Second stage regulators are not used for decreasing medium pressure and it must be installed downstream of a first stage regulator for safe and proper operation. Any regulator seen installed next to a building is a second stage regulator. Second stage regulators work with propane/ LPG/ Gases at a pressure supplied by the first stage regulator (inlet pressure) and further decrease that to a pressure that can be used by appliances (outlet pressure). Keep in mind that second stage regulators are not designed to work with varying tank pressures. Second stage regulators are only designed to operate in combination with first stage regulators. One cannot work without the other.



Conditioning Chamber
Humidity Chamber  
Twist Tester  
Coating Thickness Tester  